C&S OLR TR2D09312 A A Specification

  • Sensor Type
  • Thermal
  • Connectivity Type
  • Screw Terminal
  • Frequency
  • 50/60 Hz
  • Load Capacity
  • 9-13 Amp
  • Automation Grade
  • Automatic
  • IP Rating
  • IP20
  • Remote Control
  • Yes
  • Mounting Type
  • Direct/Panel Mount
  • Phase
  • Three Phase
  • Weight
  • Approx. 300g
  • Features
  • Adjustable current setting, Trip Class 10A, Phase failure protection
  • Control Type
  • Manual Reset
  • Application
  • Motor Protection
  • Material
  • Plastic and Metal
  • Power
  • 9-13A
  • Temperature
  • -20°C to 60°C
  • Voltage
  • 690V AC
  • Trip Class
  • 10A
  • Model No.
  • TR2D09312
  • Type
  • Overload Relay
  • Current Adjustment Range
  • 9 - 13A
  • Auxiliary Contact
  • 1NO + 1NC
  • Conformity
  • IEC 60947-4-1
 
 

About C&S OLR TR2D09312 A A



Experience the crowning touch in motor protection with the C&S OLR TR2D09312-now available at an incredible Price Cut! This top-notch overload relay is trending among industry leaders for its robust versatility and opulent build. Designed for precision, it features an adjustable current range (9-13A), phase failure protection, and conforms to IEC 60947-4-1 standards. Suitable for three-phase, 690V AC systems, its automatic, thermal sensor-based safety elevates operational reliability. Distributors, manufacturers, and suppliers across India trust this trending solution for seamless motor surveillance and trip class 10A performance.

Expert Application Across Industrial Plants

The C&S OLR TR2D09312 is purpose-built for motor protection in power plants, manufacturing units, and processing sites. Its robust structure and direct/panel mounting compatibility make it ideal for installation at motor control panels or machinery boards. Direction for use is straightforward; simply wire the relay via the screw terminals, adjust the current setting (9 to 13A), and it will automatically safeguard motors against overload and phase failure, ensuring uninterrupted facility operations.


Flexible Payment, Sample Policy & Export Reach

For your convenience, Order Completion is seamless with flexible payment terms including advance and credit options. Goods Transport is managed efficiently to guarantee timely delivery nationwide and across our main export markets in Asia, Africa, and the Middle East. We offer sample policies tailored to our clients' project needs, ensuring confidence before bulk orders. Competitive List Prices and reliable dispatch processes make us a preferred supplier for international distributors and traders.


FAQ's of C&S OLR TR2D09312 AA :


Q: How does the C&S OLR TR2D09312 protect electric motors?

A: The relay provides automatic thermal overload and phase failure protection by monitoring current levels and instantly disconnecting the motor if unsafe conditions are detected, thus preventing equipment damage.

Q: What is the typical process for installing this overload relay?

A: Installation involves mounting the relay directly on panels or boards, connecting the screw terminals to the motor circuit, setting the desired current adjustment (9-13A), and ensuring proper auxiliary contact connections.

Q: When should I consider using the TR2D09312 overload relay in my plant?

A: This relay is recommended whenever precise overload protection is required for three-phase motors in industrial plants, especially where automatic reset and phase failure defense are crucial.

Q: What are the main benefits of choosing the C&S OLR TR2D09312?

A: Users gain a top-notch, reliable device that minimizes machine downtime, prevents motor burn-outs, and offers compliance with international standards-all with an attractive price point.

Q: Where can this relay be applied on-site?

A: It can be installed in motor control panels, distribution boards, or directly on machinery, providing versatile protection across multiple plant locations.

Q: What is included in the sample policy for this product?

A: The sample policy allows clients to request product samples for evaluation before placing larger orders, ensuring complete satisfaction with performance and compatibility.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Industrial Automation Systems Category

MULTISPAN TC49 A2 - N1 - R

MULTISPAN TC49 A2 - N1 - R

Price 743 INR / Piece

Minimum Order Quantity : 1 Piece

Voltage : 230V AC

Frequency : 50/60 Hz

Material : ABS Plastic

Features : Digital Display, Parameter Locking

MULTISPAN PS24-10A-0P

MULTISPAN PS24-10A-0P

Price 3437.5 INR / Piece

Minimum Order Quantity : 1 Piece

Material : Plastic Metal

Features : High accuracy

C&S CONTACTOR LC1FDP400AE M7

C&S CONTACTOR LC1FDP400AE M7

Price 29426.10 INR / Piece

Minimum Order Quantity : 1 Piece

Voltage : 220240 Volt (v)

Frequency : 50 Hertz (HZ)

MULTISPAN UTC114

MULTISPAN UTC114

Price 814.00 INR / Piece

Minimum Order Quantity : 1 Piece

Voltage : 100240 AC Volt (v)

Frequency : 50 Hertz (HZ)

Features : Best Quality